Alpha Technologies FXM350 SNMP OID
Admin May 28, 2025 0

Unlocking the Power of Alpha Technologies FXM350 SNMP OID: A Complete Guide

In today’s world of mission-critical systems and remote network management, intelligent power monitoring has become more important than ever. One standout product in this space is the Alpha Technologies FXM350 — a compact and robust UPS (Uninterruptible Power Supply) system known for its reliability in telecom and industrial environments.

But what really takes the FXM350 to the next level is its SNMP (Simple Network Management Protocol) capability, especially when paired with OIDs (Object Identifiers). If you’ve ever wondered how to integrate this UPS into your network management system or monitor it efficiently, this is the guide you’ve been looking for.

Let’s explore what the Alpha Technologies FXM350 SNMP OID is all about, and how you can use it to gain full control and visibility over your power systems.


What is the Alpha Technologies FXM350?

The Alpha FXM350 is a highly efficient UPS designed to provide backup power and conditioning for sensitive electronic equipment. It’s widely used in telecommunications, security systems, industrial applications, and more. Key features include:

  • 350W output suitable for network equipment
  • Rugged build for harsh environments
  • Extended battery support
  • Remote monitoring via SNMP and web interface
 Alpha Technologies FXM350 SNMP OID

The FXM350 is compact but packed with intelligence — and this is where SNMP OIDs come into play.


Understanding SNMP and OIDs

Before diving into FXM350 specifics, it’s important to understand what SNMP and OIDs are:

  • SNMP (Simple Network Management Protocol) allows network administrators to monitor and manage network devices from a central location.
  • OIDs (Object Identifiers) are unique identifiers used in SNMP to reference specific pieces of information on a device — such as battery status, input voltage, or temperature.

Think of SNMP as the communication protocol, and OIDs as the language used to ask devices questions like:

“What’s your battery voltage?”

“Are you currently online or running on battery?”

“How much runtime is left?”

With the right OIDs, you can build powerful dashboards, receive alerts, and automate responses to changing conditions.


Why Use SNMP OIDs with Alpha FXM350?

The Alpha Technologies FXM350 SNMP OID set allows you to monitor nearly every aspect of the UPS remotely. Whether you’re managing a single location or a network of thousands of devices, SNMP simplifies the process.

Benefits include:

  • Real-time monitoring: Get instant updates on power status, battery levels, and alarms.
  • Remote management: No need to be on-site to know if your system is operating correctly.
  • Automation: Integrate with network management systems (NMS) like PRTG, Zabbix, or Nagios.
  • Scalability: Easily manage multiple UPS units across various locations.

Commonly Used Alpha Technologies FXM350 SNMP OIDs

Here are some commonly used SNMP OIDs for the FXM350:

FunctionSNMP OIDDescription
Input Voltage.1.3.6.1.4.1.3052.10.1.1.1.1Monitors the voltage entering the UPS
Output Voltage.1.3.6.1.4.1.3052.10.1.1.1.2Monitors the voltage going to the load
Battery Voltage.1.3.6.1.4.1.3052.10.1.1.1.3Indicates current battery voltage
Temperature.1.3.6.1.4.1.3052.10.1.1.1.4Internal temperature of the UPS unit
Alarm Status.1.3.6.1.4.1.3052.10.1.1.1.5Provides alarm/error state of the device
Runtime Remaining (mins).1.3.6.1.4.1.3052.10.1.1.1.6Shows estimated runtime left on battery

Pro Tip: Always refer to the latest Alpha Technologies MIB file to get the complete list of OIDs supported by your firmware version.


How to Use SNMP OIDs with FXM350

Using SNMP with the FXM350 is easier than you might think. Here’s a step-by-step guide:

1. Connect Your FXM350 to the Network

Make sure your FXM350 has an IP address and is reachable over the network. This is usually configured through its web interface or console port.

2. Enable SNMP Access

Log in to the FXM350’s web GUI and go to the SNMP settings. Enable SNMP and set the community string (default is usually “public”).

3. Download the MIB File

Alpha Technologies provides a MIB file that defines the OIDs and what each one represents. This file is essential for integrating with SNMP tools.

4. Use an SNMP Tool

Popular tools like SNMPWalk, PRTG, or Zabbix can poll the FXM350 using the OIDs. Just input the IP, community string, and the desired OIDs.

5. Set Traps and Alerts

You can configure the FXM350 to send SNMP traps when something goes wrong — such as power failure, high temperature, or low battery.


Real-Life Use Case: Telecom Tower Monitoring

Imagine managing 500+ telecom towers across rural areas. Without SNMP, you’d have to send technicians regularly to check if the UPS systems are online.

With Alpha Technologies FXM350 SNMP OID integration, you can:

  • See power status for every tower in one dashboard
  • Get real-time alerts when a tower loses utility power
  • Automate ticket creation for field teams
  • Extend battery lifespan with proactive maintenance

This not only reduces operational costs but also improves network uptime.


Troubleshooting SNMP on the FXM350

Problem: OIDs return “No Such Object”

  • Fix: Check if the OID is correct and if SNMP is enabled. Use the latest MIB file.

Problem: SNMP timeout or unreachable

  • Fix: Verify the IP address, SNMP community string, and firewall settings.

Problem: MIB browser shows unknown OIDs

  • Fix: Load the Alpha Technologies MIB into your SNMP tool to get readable names.

Final Thoughts

The Alpha Technologies FXM350 SNMP OID capability transforms this compact UPS into a powerful tool for modern network management. Whether you’re a system administrator, IT technician, or a network engineer, using SNMP and OIDs with the FXM350 can help you:

  • Prevent outages
  • Monitor systems 24/7
  • Reduce manual maintenance
  • Extend device life through smart insights

If you’re already using the FXM350, and you’re not taking advantage of SNMP OIDs — you’re missing out on one of its most powerful features.


Ready to Get Started?

  1. Download the MIB file from Alpha’s website.
  2. Install an SNMP monitoring tool.
  3. Start polling your FXM350 devices.
  4. Automate alerts and reporting for smarter operations.

Integrate. Monitor. Relax.
That’s the Alpha Technologies FXM350 SNMP OID advantage.


 Frequently Asked Questions (FAQs)

What is the Alpha Technologies FXM350 used for?

The Alpha FXM350 is a compact UPS (Uninterruptible Power Supply) designed to deliver reliable backup power for telecom, security, and industrial equipment. It’s ideal for outdoor and remote environments where consistent power is crucial.


What does SNMP mean in the FXM350?

SNMP stands for Simple Network Management Protocol. In the FXM350, SNMP allows network administrators to remotely monitor and manage the UPS — from checking power status to receiving alerts during outages.


What is an SNMP OID?

An OID (Object Identifier) is a numeric string used by SNMP to identify specific data points on a device. For example, you can use OIDs to request battery voltage, runtime remaining, or temperature readings from the FXM350.


Why are SNMP OIDs important for the FXM350?

SNMP OIDs let you access live performance data from the FXM350 remotely. With the right OIDs, you can:

  • Monitor real-time power metrics
  • Set up alerts for power failures
  • Analyze trends in battery usage
  • Automate maintenance tasks

Can I integrate the FXM350 with tools like PRTG or Zabbix?

Yes! The FXM350 supports SNMP, making it compatible with most network monitoring tools such as PRTG, Zabbix, Nagios, and more. Simply load the Alpha MIB file and start polling the OIDs.


How do I find the correct OIDs for my FXM350?

Alpha Technologies provides a MIB (Management Information Base) file, which contains all supported OIDs. You can download this from their official support page or get it from your FXM350 web interface if SNMP is enabled.


Is it secure to use SNMP with the FXM350?

By default, SNMP v1 and v2c are supported, which use community strings like “public” or “private”. For better security, consider using SNMPv3, which offers authentication and encryption — if supported by your FXM350 firmware.


What are some must-use OIDs for monitoring?

Here are a few essential ones:

MetricOID
Input Voltage.1.3.6.1.4.1.3052.10.1.1.1.1
Output Voltage.1.3.6.1.4.1.3052.10.1.1.1.2
Battery Voltage.1.3.6.1.4.1.3052.10.1.1.1.3
Temperature.1.3.6.1.4.1.3052.10.1.1.1.4
Runtime Remaining.1.3.6.1.4.1.3052.10.1.1.1.6

What happens if the FXM350 loses power?

If utility power is lost, the FXM350 switches to battery mode instantly. If SNMP is configured, it can send traps/alerts to your monitoring system to notify you of the power event in real time.


Can I receive automatic alerts from the FXM350?

Yes! The FXM350 supports SNMP traps, which are automatic alerts triggered by specific events — like low battery or high temperature. Just configure the trap receiver in the SNMP settings of the FXM350.

Category: 

Leave a Comment